Tuesday, February 25, 2014

carrier-bypass-humidifier-installed-wrong

Carrier bypass humidifier installed wrong?


My brother and I both bought the same house from the same builder. The HVAC system is a dual-furnace, dual-A/C setup and we both opted for humidifiers. Yesterday I noticed that on my furnaces the Carrier bypass humidifier is installed on the hot-air duct coming out of the furnace, with the bypass duct coming into the humidifier from the cold-air return duct. My brother's is installed the opposite way - i.e. the Carrier unit is attached to the cold-air return duct going into the furnace, with the bypass ducting being attached to the hot-air vent coming from the furnace. Which one is correct? :confused: I assume that our builder will end up having to fix at least one of the setups... grr. :mask: l8r) Did some research, and I'm still confused, as the installation instructions aren't 100% clear either. It seems like Carrier is saying to install the humidifier above the furnace (i.e. on the hot-side), but they could have been a little bit clearer. The installation instructions state this: ... and the Humidistat install instruction show this: l8r) I am not able to get in the link.. You must of signed up for member ship there? on a bypass unit, it really don't matter what side the unit is on. I now a lot of us prefer the unit on the return than supply. Just less chance of water damage to the furnace if something did fail on you. If the unit was on the supply, and the tray over flowed, the water then will flow down into the furnace, and may damage the motor. If there is no room on return, then supply is the next step. Ok, thanks. So the air flow through the bypass humidifier is the same either way? l8r) Right, the air will flow from the supply duct into the return, so either way the air is going to go over the pad one way or another.








Related Posts:




  • Diy install aprilaire 500 humidifier couple questions

    DIY install Aprilaire 500 humidifier? Couple questions...I've contemplated putting in a whole-house humidifier a couple times over the past few years, and I'm now fearing the coming dry winter air...


  • Beginner moving humidistat for generalaire humidifier model 1042lh

    beginner moving humidistat for generalaire humidifier model 1042LHHi, I bought a house recently and have been trying to learn more about the humidifier that was installed. I have a Generalaire byp...


  • Carrier furnace limit switch is tripping

    Carrier Furnace Limit Switch is TrippingI have Carrier Furnace model 58PAV111-20 The limit switch keeps trips after running for about 5 minutes. I can reset the switch but it trips. I looked on li...


  • Carrier furnace led codes where do i find their meaning

    Carrier Furnace LED Codes - where do I find their meaning?I have a Carrier Gas Furnace 58MXA100-20 that isn't working. After reset, it's LED code blinks 1short - 2long for a while then 2short - 3l...


  • Common post for furnace humidifier

    Common Post for Furnace / HumidifierI am reposting since I was in the wrong forum section. I am unable to delete my other post, however. Here goes: I have a White-Rodgers 50a51-405 Circuit board i...